Join us you will be able to get the following rights
Get fresh academic and clinical information
Sign up for exclusive endoscopy contests and training courses
Use online training software
Watch the LIVE of academic conferences and surgery
Comparison Between Linked Color Imaging and Blue Laser Imaging for Improving the Visibility of Flat Colorectal Polyps: A Multicenter Pilot Study
Comparison Between Linked Color Imaging and Blue Laser Imaging for Improving the Visibility of Flat Colorectal Polyps: A Multicenter Pilot Study
N Yoshida, T Hisabe, H Ikematsu, H Ishihara… - Digestive diseases and Sciences, 2020
Introduction: Linked color imaging (LCI) and blue laser imaging-bright (BLI-b) improve the visibility of gastrointestinal lesions. In this multicenter study, we compared the effects of LCI and BLI-b on the visibility of flat polyps with visibility scores and color difference (CD) values, including fast-withdrawal and large-monitor observation.
Methods: We recorded 120 videos of 40 consecutive flat polyps (2–20 mm), adenoma, and sessile serrated adenoma and polyp (SSA/P), using white light imaging (WLI), BLI-b, and LCI from July 2017 to December 2017. All videos were evaluated by eight endoscopists according to a published polyp visibility score of 4 (excellent) to 1 (poor). Additionally, 1.5 ×faster and 1.7 ×sized videos were evaluated. Moreover, we calculated the CD values for each polyp in three modes.
Results: The mean LCI scores (3.1 ± 0.9) were significantly higher than the WLI scores (2.5 ± 1.0, p < 0.001) but not significantly higher than the BLI-b scores (3.0 ± 1.0). The scores of faster videos on LCI (3.0 ± 1.1) were significantly higher than WLI (2.0 ± 1.0, p < 0.001) and BLI-b (2.8 ± 1.1, p = 0.03). The scores of larger-sized videos on LCI were not significantly higher than those of WLI or BLI-b. The CD value of LCI (18.0 ± 7.7) was higher than that of WLI (11.7 ± 7.0, p < 0.001), but was not significantly higher than that of BLI-b (16.6 ± 9.6). The CD value of LCI was significantly higher than that of BLI-b for adenoma, but the CD value of BLI-b was significantly higher than that of LCI for SSA/P.
Conclusions: The superiority of LCI to BLI-b was proven for the visibility of adenoma and fast observation.
声明
富士胶片内镜世界(LIFE World)所登载的内容及其版权和使用权归作者本人与富士胶片所有。如发现会员擅自复制、更改、公开发表或其他以盈利为目的的使用,富士胶片将追究其法律责任。网站信息中涉及的治疗手技皆为术者个人针对该名患者特定体质及健康状况所采取的手法;术者对器械和药品种类的选择,也受到手术发生时间、地点等诸多因素的影响。因而相关内容及信息仅供会员参考。如盲目使用网站信息中涉及的治疗手技而发生意外,恕富士胶片及本网站对此不承担任何责任。