The efficacy of tumor characterization and tumor detectability of linked color imaging and blue laser imaging with an LED endoscope compared to a LASER endoscope

收藏已收藏
692
LCI文献

The efficacy of tumor characterization and tumor detectability of linked color imaging and blue laser imaging with an LED endoscope compared to a LASER endoscope

2021/09/06LCI文献
收藏已收藏
692
查看全文

N Yoshida, O Dohi, K Inoue, S Sugino… - International Journal of Colorectal Disease, 2020

 

Objectives: An endoscope with a light-emitting diode (LED) light source which has a 2-mm close-distance observation function without magnification, has been marketed, enabling linked color imaging (LCI) and blue laser imaging (BLI) for tumor detection and characterization. We analyzed the efficacy of a LED endoscope compared to a LASER endoscope.

 

Methods: We retrospectively reviewed 272 lesions observed using the LED endoscopic system (Fujifilm Co., Tokyo, Japan) from May 2018 to September 2019. The Japanese NBI Classification was used for tumor characterization. We analyzed the diagnostic accuracy and confidence level. Sixty-one lesions observed with both the LED and magnified LASER endoscopes were also analyzed to compare the diagnostic accuracy. Regarding the tumor detectability, we calculated color difference values (CDVs) and brightness values (BVs) of white-light imaging, BLI, and LCI modes between the two endoscopes for each tumor.

 

Results: The mean polyp size was 9.2 ± 11.3 mm. Histology showed 71 sessile serrated lesions, 193 adenoma and high-grade dysplasias, and 8 T1 cancers. The diagnostic accuracy of tumors ≥ 10 and < 10 mm was 72.0% and 92.9% (p < 0.001), respectively and the high confidence rate was 93.8%. The diagnostic accuracy of LED (77.0%) was a little higher than that of LASER without magnification (65.6%, p = 0.16) but was not inferior to that of LASER with magnification (82.0%, p = 0.50). The respective CDVs of LED and LASER endoscopes were 20.6 ± 11.2 and 21.6 ± 11.2 for LCI (p = 0.30), and the respective BVs were 210.0 ± 24.2 and 175.9 ± 21.1 (p < 0.001).

 

Conclusions: A LED endoscope with close-distance observation improved tumor detection and characterization due to high brightness.