升级至高级会员解锁所有内容!

移步至“会员中心”,完善资料并上传医师执照,即可升级至高级会员权限,浏览本站所有内容,包括使用培训软件、参与大赛和培训报名等。

去上传

放大内镜使用联动成像技术和靛胭脂观察小的胃凹陷性病变

收藏已收藏
804
LCI文献

放大内镜使用联动成像技术和靛胭脂观察小的胃凹陷性病变

2022/03/11LCI文献
收藏已收藏
804
查看全文

放大内镜使用联动成像技术联合靛胭脂观察小的胃凹陷性病变

Magnified endoscopic observation of small depressed gastric lesions using linked color imaging with indigo carmine dye



Y Kitagawa, T Hara, D Ikebe, R Nankinzan… - Endoscopy, 2018

结 论

使用联动成像技术结合靛胭脂染色放大(M-Chromo-LCI)可望成为准确诊断胃病变的一种有效方法。


Conclusions: M-Chromo-LCI is expected to become a useful modality for the accurate diagnosis of gastric lesions.

01

背景与研究目的

使用联动成像技术联合靛胭脂染色放大(M-Chromo-LCI)能够对浅表胃黏膜进行立体增强和图像放大颜色观察。本研究探讨M-Chromo-LCI在胃病变鉴别诊断中的应用价值。


Background and study aims: Magnifying linked color imaging with indigo carmine dye (M-Chromo-LCI) enables sterically enhanced and color image-magnified observation of the superficial gastric mucosa. This study investigated the usefulness of M-Chromo-LCI for the differential diagnosis of gastric lesions.

02

患者和方法

用常规白光成像(C-WLI)、放大蓝光成像(M-BLI)和M-Chromo-LCI检查100个连续的小凹陷病灶。检查的内镜图像由三位专家和三位非专家审核。比较不同模式间的诊断准确性和观察者间的一致性。


Patients and methods: 100 consecutive small depressed lesions were examined with conventional white-light imaging (C-WLI), magnifying blue-laser imaging (M-BLI), and M-Chromo-LCI. Endoscopic images were reviewed by three experts and three non-experts. Diagnostic accuracy and interobserver agreement were compared among the modalities.

03

研究结果

对于专家而言,M-BLI的诊断准确率显著高于C-WLI (82.7% vs 67.0%;P < 0.001)。M-Chromo-LCI与M-BLI的诊断准确率无显著差异(87.7% vs 82.7%;P = 0.31)。对于非专家而言,M-BLI的诊断准确性显著高于C-WLI (69.3% vs. 52.3%;P < 0.001)。M-Chromo-LCI比M-BLI的诊断准确率高(79.7%比69.3%;P = 0.005)。M-Chromo-LCI观察组间一致性最高。


Results: For experts, M-BLI showed a significantly higher diagnostic accuracy than C-WLI (82.7 % vs. 67.0 %; P < 0.001). The diagnostic accuracy of M-Chromo-LCI was not different from M-BLI (87.7 % vs. 82.7 %; P = 0.31). For non-experts, M-BLI showed a significantly higher diagnostic accuracy than C-WLI (69.3 % vs. 52.3 %; P < 0.001). M-Chromo-LCI additionally showed a significantly higher diagnostic accuracy than M-BLI (79.7 % vs. 69.3 %; P = 0.005). M-Chromo-LCI had the highest interobserver agreement for each group.


点击查看原文

声明

富士胶片内镜世界(LIFE World)所登载的内容及其版权和使用权归作者本人与富士胶片所有。如发现会员擅自复制、更改、公开发表或其他以盈利为目的的使用,富士胶片将追究其法律责任。网站信息中涉及的治疗手技皆为术者个人针对该名患者特定体质及健康状况所采取的手法;术者对器械和药品种类的选择,也受到手术发生时间、地点等诸多因素的影响。因而相关内容及信息仅供会员参考。如盲目使用网站信息中涉及的治疗手技而发生意外,恕富士胶片及本网站对此不承担任何责任。

最新留言